The company is committed to the production and development of all types of medium and high-end Leadshine Servo Driver, Robot Joint Actuator, Ir Speed Sensor. Relying on superior quality and excellent post-sales, our products sell well all over the world. We keep our dreams alive and are committed to building a responsible and sentimental company, drawing up a beautiful blueprint for the future with our customers.

Parameter table
Parameter | AC servo drive | CTDH1200 |
Size | 112.5*90mm | Customized |
Voltage | 18~60V | 18~60V |
Controller supply current | 30A | 30A |
power | 1500W | <10Kw |
Support sensor | With hall, incremental encoder (can support 4096 Wires) | No hall, with hall, incremental encoder (can support 4096 Wires) |
Exception protection | Locked rotor, undervoltage, overcurrent | Locked rotor, undervoltage, overcurrent |
Signal communication | 485 | CAN/485 |
The above parameters are for reference only. Our product technology is constantly updated and upgraded. At the same time, we also accept the customization and development of customers.
3.Product details



4. Factory and qualification




5. Instructions and precautions
Fault reason: the command signal is not to the driver signal ground.
Processing method: connect the command signal ground with the driver signal ground.
Fault: after power on, the LED of the driver is not on Fault reason: the power supply voltage is too low, less than the minimum voltage requirements.
Treatment: check and increase the power supply voltage.
Fault: when the motor rotates, the LED light flashes
1. Fault reason: Hall phase error.
Treatment: check whether the motor phase setting switch (60? / 120?) is correct. Most brushless motors have a 120? Phase difference.
2. Fault cause: Hall sensor failure
Treatment method: detect the voltage of hall a, Hall B and Hall C when the motor rotates. The voltage should be between 5VDC and 0.
Fault: LED remains red all the time
Cause of failure: there is a fault.
Treatment method: cause: over voltage, under voltage, short circuit, overheating, driver forbidden, hall invalid.
In the use of servo system, can servo-on be used as the signal to control the motor off-line so as to directly rotate the motor shaft?
Although the motor can be offline (in free state) when the srv-on signal is disconnected, do not use it to start or stop the motor. Frequent use of it may damage the drive. If the off-line function needs to be realized, the switch of control mode can be adopted: assuming that the servo system needs position control, the control mode selection parameter no02 can be set to 4, that is, the first mode is position control, and the second mode is torque control. Then C-mode is used to switch the control mode: in position control, the signal C-mode is opened to make the driver work in the first mode (i.e. position control); when it is necessary to be offline, the signal C-mode is closed to make the driver work in the second mode (i.e. torque control). Because the torque command input trqr is not connected, the motor output torque is zero, thus realizing offline.
Our products are exported towards the USA, the UK and so on, enjoying a fantastic reputation amongst customers for Delta 200W Single Phase 220V AC Servo Motor Drive Asd-B2-0221-B. We provide long-term professional knowledge training to employees to establish the quality awareness of all employees, and strictly implement the standardization and internationalization of enterprise management to ensure product quality. With the progress of internationalization and globalization, we continue to improve our strategic layout, broaden our sales network and market space, and be able to provide customers with products and services in a timely and efficient manner.
Hot Tags: ac servo drive, China, manufacturers, suppliers, wholesale, custom, high quality, Patrol Robot, Magnetic Encoder, Robotic Motor, 36v Brushless Motor, Universal Mobile Robot, Brushed Dc Servo Driver
[[ProKeywords]]SPEC DATA
Send Inquiry